6 research outputs found
Use of the Brucella IgM and IgG flow assays in the serodiagnosis of human brucellosis in an area endemic for brucellosis
The clinical utility of two complementary tests for brucellosis, the Brucella IgM and IgG flow assays, was evaluated in a hospital in eastern Turkey. The results show that the flow assays are convenient diagnostic tests for use in endemic areas. A positive result in the flow assays was obtained in 91% and 97% of the admission sera from adult and pediatric patients with brucellosis, respectively, and the sensitivity at admission was 100% for culture-confirmed brucellosis. The assay system performed equally well in diagnosing patients at different stages of illness including patients with acute, subacute, or chronic disease and with relapse. The results of the flow assays correlated well with those of a serum agglutination test at a cut-off > or =1:160. The agreement was 92%. Application of the flow assays on serum samples collected during a village survey for brucellosis after an outbreak demonstrated their diagnostic potential as field test
Recommended from our members
Six-year multicenter study on short-term peripheral venous catheters-related bloodstream infection rates in 727 intensive care units of 268 hospitals in 141 cities of 42 countries of Africa, the Americas, Eastern Mediterranean, Europe, South East Asia, and Western Pacific Regions: International Nosocomial Infection Control Consortium (INICC) findings
Short-term peripheral venous catheter-related bloodstream infection (PVCR-BSI) rates have not been systematically studied in resource-limited countries, and data on their incidence by number of device days are not available.
Prospective, surveillance study on PVCR-BSI conducted from September 1, 2013, to May 31, 2019, in 727 intensive care units (ICUs), by members of the International Nosocomial Infection Control Consortium (INICC), from 268 hospitals in 141 cities of 42 countries of Africa, the Americas, Eastern Mediterranean, Europe, South East Asia, and Western Pacific regions. For this research, we applied definition and criteria of the CDC NHSN, methodology of the INICC, and software named INICC Surveillance Online System.
We followed 149,609 ICU patients for 731,135 bed days and 743,508 short-term peripheral venous catheter (PVC) days. We identified 1,789 PVCR-BSIs for an overall rate of 2.41 per 1,000 PVC days. Mortality in patients with PVC but without PVCR-BSI was 6.67%, and mortality was 18% in patients with PVC and PVCR-BSI. The length of stay of patients with PVC but without PVCR-BSI was 4.83 days, and the length of stay was 9.85 days in patients with PVC and PVCR-BSI. Among these infections, the microorganism profile showed 58% gram-negative bacteria: Escherichia coli (16%), Klebsiella spp (11%), Pseudomonas aeruginosa (6%), Enterobacter spp (4%), and others (20%) including Serratia marcescens. Staphylococcus aureus were the predominant gram-positive bacteria (12%).
PVCR-BSI rates in INICC ICUs were much higher than rates published from industrialized countries. Infection prevention programs must be implemented to reduce the incidence of PVCR-BSIs in resource-limited countries
International Nosocomial Infection Control Consortium (INICC) national report on device-associated infection rates in 19 cities of Turkey, data summary for 2003-2012
Background: Device-associated healthcare-acquired infections (DA-HAI) pose a threat to patient safety, particularly in the intensive care unit (ICU). We report the results of the International Infection Control Consortium (INICC) study conducted in Turkey from August 2003 through October 2012
International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module
•We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's.
Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific.
Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days.
Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs.
Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically
International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module
We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN